DEUTSCH

Air temperature and relative humidity

sensor air temperature and relative humidity


Hygro-thermo sensor compact

The unit is used for measuring the air temperature and the humidity two meters above surface. The sensors are a capacitive element and a Pt 100 thermo couple.
They are installed in an rain and radiation protective housing wich minimises mismeasurement. The housing is also forced ventilated to prevent the formation of a so called micro-clima inside.

Metering range humidity: 0...100% r.H. (±2%)
Metering range Temperature: -30...+70°C (±0,1K)

Air pressure



Barometer B-278-1T

For measuring the air pressure an capacitive ceramic absolute-pressure sensor is used. To prevent negative environmental influences the sensor is direcly installed in the datalogger housing.

Metering range: 800...1060hPa (±0,3hPa @20°C)
Temperature range: -30...+70°C (±0,1K)

Wind speed



Windspeed sensor 4.3303.22.008

For measuring the horizontal Wind speed component a semi-shell anemometer is used. The unit is build as a inerta-reduced ball-bearing triple-armed semi-shell star made of aluminium. The rotation is converted to a digital signal by an optoelectronical sensor. The unit could be heated in winter period.

Measureing range: 0,5...75 m/s (± 2%)
Resolution: 0,05 m

Wind direction



Wind direction sensor 4.3121.32.000

For measuring the horizontal Wind direction component a ball bearing aluminium vane is used. Every 2ms a digital signal is generated by a optoelectronical angle encoderer (8-bit parallel 2,5° resolution).

Measuring range: 0...360°
resolution: 2,5°

Global radiation



Pyranometer CSD 6

For measuring the global radiation a pyranometer is used. Sunlight impinges on a kind of solar cell, that produces a voltage analogue to the intense of the radiation. this voltage is calculated in a value by the datalogger.

Measuring range: 0...2000 W/m²
Spectral range: 310...2800 nm

Sunshine duration

Precipitation

Precipitation status

Soil temperature



Temperature sensor 2.1235.00.010

A PT100 thermocouple is positioned 5cm above surface level so the laminar layer temperature could be measured.

Measuring range: -30...+100°C
Accuracy:0,1K @0°C

 


All Photos by courtesy of Thies Clima, Göttingen
Um unsere Webseite für Sie optimal zu gestalten und fortlaufend verbessern zu können, verwenden wir Cookies. Weitere Informationen und die Möglichkeit zum Widerruf finden Sie in unserer Datenschutzerklärung.
Seite drucken